The L Series, L7, LM7 and LM8, is a family of fixed setting temperature limit controls whose design is failsafe. The L7 is auto reset, whilst LM7 and LM8 are manual reset. The operating temperatures are factory set and non-adjustable by the customer. Settings are available between 50 and 160ûC with capillary lengths from 450 - 2000mm (1000 mm standard). The L7/LM7 are SPST (single pole singlethrow) and LM8 is DPST (doublepole single throw).

DESIGN FEATURES
- Element
- Auto or manual reset
- Fail-safe (cut-out to safety)
- 16(3)A 400V ~. For LM8 ratings apply to each pole
- Variety of settings and capillary options
- Narrow profile to fit applications where space is limited
- Versions available for Class I and Class II appliances
- Versions for millivolt circuits(L7/LM7 only) available
- Simple mounting
APPLICATIONS
These controls are used on any application where protection against overheat is required. Typical applications are:
- 'Boil dry' protection for waterheaters, washing machines,dishwashers, vending machines (protection of heating elements)
- high temperature cut-out oncentral heating boilers
- blocked flue sensor on boilers with natural draft (on operation the gas supply to the burner is switched off)
- protection against overheating in panel/convector heaters
- overheat safety for AC cassette units equipped with an electric boost heater
- overheat safety on compressor discharge pipes
TECHNICAL SPECIFICATIONS (see dimensions also)
Electrical Rating
L7/LM7: 16A 400V~ resistive
3A 400V~ inductive
LM8: ratings apply to each pole
Switch
SPST break on rise of temperature
DPST (LM8) break on rise of temperature (note: for millivolt applications L7/LM7 can be supplied with goldplated contacts)
Terminals
Tab 6,3 mm
Terminal Configuration
As shown, earth terminals available if required
Approvals
Approved throughout Europe
Special versions approved for North America (see chart)
Maximum Head Temperature
At least 15°C below sensed temperature, max. 90ºC

TECHNICAL SPECIFICATIONS
Temperature Range
Fixed settings between 50ºC and 160ºC to order (factory set)
Tolerances
Standard ±8ºK On models with cut-out temperatures, 50 - 115ºC ±3ºK is available
Capillary Length
450 and 2000 mm (in accordance to customer specification)
Capillary Insulation
Available on request

TECHNICAL SPECIFICATIONS
Capillary Form
Straight or coiled (minimum diameter 6 mm) Approximately 400 mm of capillary or the complete sensing element is required for optimum sensing
Cross Ambient
Cross ambient versions with solid bulbs are available (LM7 and LM8 only). Temperature range 50 - 130ºC. The following information should be supplied with every enquiry:
- Application
- Model L7, LM7 or LM8
- Setting required
- Capillary length and sensing element (for options see Fig.3)
- Control switch temperature
- Mounting requirement (for options see Fig.2)
- Capillary insulation

Barometric Effect
The control is calibrated to cut-out within the specified tolerance at a barometric pressure of 760 mm Hg. For pressure higher (or lower) than this add (or subtract) 1ºC for every 25 mm Hg change.
This control must be applied and installed in line with local approvals and practices. Suitable earthing must be made by appliance manufacturer and installer.